Add to Cart
CCY17Y Differential Pressure Transmitter Industrial Equipment Pharmaceuticals And Biotechnology Flow Monitoring
The CCY17 differential pressure transmitter is designed for industrial applications to measure the differential pressure value of liquids or gases, is not only compact, but also of excellent quality, ideal for general industry, and cost-effective.
It also has diversified advantages such as output signal, range and electrical connection, which is convenient to match different working conditions.
Base parameters | ||||||||||
Measuring medium | Liquids, fluids, gases (compatible with contact materials) | |||||||||
Pressure mode | Differential pressure | |||||||||
Media temperature | -40~85℃ | |||||||||
On-time | 20ms | |||||||||
Accuracy class | 0.25%FS (differential pressure range to rated range ratio ≥1:2.5) 0.5%FS (differential pressure range to rated range ratio <1:2.5) With repeatability≤ 0.05%FS, hysteresis ≤0.05%FS Meter display accuracy 0.5%FS<b15>, digital tube (LED) display Note: Reference condition temperature 25~86 °C, Atmospheric pressure 106~45kPa, humidity 75~<>%RH. | |||||||||
Response frequency | Analog output≤ 30Hz, digital output≤5Hz | |||||||||
Stable performance | ± 0.1% FS/year | |||||||||
Temperature compensation | -10~70℃ | |||||||||
Temperature drift | ±0.01%FS/°C (temperature compensation range) ±0.05%FS/°C (outside temperature compensation range) | |||||||||
Degree of protection | IP65 (no display) IP54 (with display) Note: The above protection level refers to the electrical connection is complete | |||||||||
Durable performance | 10X10⁶ times (lower range to upper range cycles) | |||||||||
Overall weight | No display≈ 415g Yes display≈460g | |||||||||
resolution | Analog output 0.01%FS, digital output 0.05%FS | |||||||||
Output power | ||||||||||
Power supply range | 9~36VDC 15~36VDC 3~5VDC | |||||||||
Current type | ≤0.02Us(W) | |||||||||
Maximum power | ||||||||||
4-20mA | Yes/No Display≤0.02Us(W) | |||||||||
RS485 | With display ≤0.02Us(W), no display ≤0.015Us(W) | |||||||||
0~10VDC | With display ≤0.02Us(W), no display ≤0.008Us(W) | |||||||||
0~5VDC | With display ≤0.02Us(W), no display ≤0.008Us(W) | |||||||||
1~5VDC | With display ≤0.02Us(W), no display ≤0.008Us(W) | |||||||||
0.5~2.5VDC | No display≤0.001Us(W) | |||||||||
Load characteristics | ||||||||||
Voltage type | ≥10kΩ | |||||||||
Current type | No display load≤ {(Us-7.5)÷0.02}Ω with display load≤{(Us-12)÷0.02}Ω (US=supply voltage) | |||||||||
Environmental conditions | ||||||||||
Ambient temperature | -40~85℃ | |||||||||
Ambient humidity | 0%~95%RH(no condensation, no condensation) | |||||||||
Overall material | ||||||||||
diaphragm | 316L stainless steel (contact with the medium to be measured) | |||||||||
Process connection | 304 stainless steel (contact with the medium to be measured) | |||||||||
enclosure | 304 stainless steel | |||||||||
Seals | Nitrile rubber O-ring | |||||||||
Display the shell | ABS Engineering Plastics (LED Display) | |||||||||
Hirschman plug | ABS engineering plastics | |||||||||
Mechanical stability | ||||||||||
Seismic performance | 10g(20… 2000Hz) conforms to IEC60068-2-6 standard | |||||||||
Impact resistance | 500g/ms conforms to IEC60068-2-27 standard | |||||||||
Electrical protection | ||||||||||
Short-circuit protection | perpetual | |||||||||
Anti-polarity protection | No damage, but not working | |||||||||
Insulation resistance | ≥100MΩ 500VDC | |||||||||
Dielectric strength | 500VAC | |||||||||
Output limits | ||||||||||
4-20mA | 4~20mA | |||||||||
RS485 | 0~2000 | |||||||||
0~10VDC | 0.001VDC~10VDC | |||||||||
0~5VDC | 0.001VDC~5VDC | |||||||||
1~5VDC | 0.001VDC~5VDC | |||||||||
0.5~2.5VDC | 0.05VDC~5VDC |