Add to Cart
CYYZ3051SAY Monocrystalline Silicon Double Remote Differential Pressure Transmitter Range 0~4kPa~1MPa 4-20mA HARTprotocol
CYYZ3051SAY monocrystalline silicon dual remote differential pressure transmitter uses monocrystalline silicon resonant sensor technology. The double-flange capillary structure realizes mechanical isolation and thermal isolation, which can cope with complex corrosive media, high temperature media and other sites. It is suitable for measuring the level, volume, density and differential pressure of liquids, gases or vapors. It has a variety of explosion-proof functions, intrinsically safe type, dust intrinsically safe type, flameproof type, and flameproof dust type.
Basic parameters | |
Measuring medium | Liquid or gas (compatible with contact materials) |
pressure type | Differential pressure |
Medium temperature | Depends on the filling fluid: Silicone oil (conventional medium, applicable medium temperature -40~205℃) High temperature silicone oil (conventional medium, applicable medium temperature -40~300℃) Mineral oil (hygienic filling fluid, applicable medium temperature -20~170℃) Fluorine Oil (special filling fluid for oxygen, applicable medium temperature -40~170℃) |
output signal | 4-20mA HART protocol |
Power supply range | 12~32VDC, 15~24VDC (intrinsically safe and explosion-proof only) |
Maximum power | ≤0.02Us(W) |
connection time | 20ms |
Stable performance | ±0.05%URL/year |
Explosion-proof level | Explosionproof type Ex d Ⅱ C T6 Gb Explosionproof dust type Ex tb IIIC T80℃ Db Intrinsically safe type Ex ia ⅡC T6 Ga dust intrinsically safe type Ex ia ⅢC T200 80℃ Da Note: Intrinsic safety must be passed through a safety barrier or intrinsically safe power supply powered by |
Protection level | IP66 Note: The above protection level refers to the level achieved after the electrical connection is complete. |
response frequency | The time constant is adjustable, in increments of 0.1 seconds, from as low as 32 seconds. If the damping time is 0, the default is 0.1 (the lowest is 0.1). |
Load characteristics | |
HART current type | Load ≤{(Us-12)÷0.02}Ω (Us=supply voltage) |
environmental conditions | |
No LCD liquid crystal display ambient temperature | -40~85℃ |
With LCD display ambient temperature | -20~70℃ |
environment humidity | 0%~95%RH (no condensation, no condensation) |
overall material | |
Diaphragm | 316L stainless steel/Hastelloy C/tantalum (contact with the measured medium) |
flange | 304/316L stainless steel |
chuck | 316L stainless steel |
Clamp block | 304 stainless steel |
Filling fluid | Silicone oil, high temperature silicone oil, mineral oil, fluorine oil |
bolt | 304 stainless steel |
case | die cast aluminum |
display window | ≈6mm explosion-proof glass |
mechanical stability | |
Anti-vibration performance | 10g(20…2000Hz) complies with IEC60068-2-6 standard |
Impact resistance | 500g/ms conforms to IEC60068-2-27 standard |
electrical protection | |
Short circuit protection | permanent |
Reverse polarity protection | No damage, but doesn’t work |
Insulation resistance | ≥100MΩ 500VDC |
Dielectric strength | 500VAC |
Output limits | |
Output minimum | 3.8mA |
Output maximum | 22mA |