Add to Cart
CYYZ36AY Mud Type Pressure Transmitter Range 0~1MPa~110MPa Accuracy 0.5%FS Construction Machinery Cement Grout
CYYZ36AY mud type pressure transmitter has careful design, compact structure, anti-vibration, frequent high-pressure impact, solid sand impact, and wear resistance, and is suitable for the measurement of mud, crude oil, wet soil and other media.
| Base parameters | |
| Measuring medium | Slurry, crude oil, wet soil, etc. (compatible with contact materials) |
| Measuring range | 0~1MPa~110MPa (see range selection table for details) |
| Type of pressure | Gauge pressure |
| Temperature compensation | -10~70℃ |
| Accuracy class | 0.5%FS |
| Response frequency | 5Hz,100Hz |
| Stable performance | ± 0.1% FS/year |
| Temperature drift | ±0.01%FS/°C (temperature compensation range) ±0.05%FS/°C (outside temperature compensation range) |
| Overall weight | ≈650g (including 5m cable) |
| resolution | Analog output 0.01%FS, digital output 0.05%FS |
| Degree of protection | IP67 |
| Output power | |
| Output signal | 4~20mA,RS485 |
| Power supply range | 9~36VDC |
| Power range | |
| Current type | ≤0.02Us(W) |
| Digital | ≤0.015Us(W) |
| Load characteristics | |
| Current type | ≤{(Us-7.5)÷0.02(Us=Supply voltage)}Ω |
| Environmental conditions | |
| Media temperature | -40~85℃ |
| Ambient temperature | -40~85℃ |
| Ambient humidity | 0%~95%RH(no condensation, no condensation) |
| Overload capacity | |
| Overload pressure | 200%,150%FS |
| Burst pressure | 400%,300%FS |
| Overall material | |
| diaphragm | 316L stainless steel (contact with the medium to be measured) |
| Process connection | 316L stainless steel (contact with the medium to be measured) |
| enclosure | 316L stainless steel (contact) |
| Seals | Fluoroelastomer Seen pressure and blasting charts (contact with the medium being measured) |
| Cable | Cable: φ5mm polyurethane shielded cable (UV protection) |
| Mechanical stability | |
| Seismic performance | 10g(20… 2000Hz) conforms to IEC60068-2-6 standard |
| Impact resistance: | 500g/ms conforms to IEC60068-2-27 standard |
| Electrical protection | |
| Short-circuit protection | perpetual |
| Anti-polarity protection | No damage, but not working |
| Insulation resistance | ≥100MΩ500VDC |
| Dielectric strength: | 500VAC |
| Output limits | |
| The output is minimal | 3.8mA,0 |
| Output maximum | 26mA,2000 |