Add to Cart
CYYZ61EY Hygienic Pressure Transmitter Pressure Range -0.1~0~4MPa Accuracy 0.25%FS 0.5%FS Medical Technology
The CYYZ61EY hygienic pressure transmitter is suitable for applications with hygienic requirements, and the wetted part and diaphragm are made of 316L material. Laser welding process is adopted, and there is no sanitary dead end. Suitable for the pharmaceutical and food industries. Optional intrinsically safe explosion-proof.
Basic parameters | |
Measuring medium | Liquids, gases (compatible with contact materials) |
Pressure range | -0.1~0~4MPa (see range selection table for details) |
Pressure mode | Gauge pressure, negative pressure, absolute pressure |
Medium temperature | -40~85℃ |
Turn-on time | 20ms |
Stable performance | ±0.1% FS/year |
Temperature compensation | -10~70℃ |
Temperature drift | ±0.01%FS/°C (within temperature compensation) ±0.05%FS/°C (outside temperature compensation) |
Explosion-proof type | Intrinsically safe Ex ia II.C T6 Ga (4~20mA output only) |
Ingress protection | IP65 (no display) IP54 (display) Note: The above protection level refers to the completion of the electrical connection |
Durable performance | 1X10⁶ cycles (number of cycles from lower range to upper range) |
Overall weight | No display≈ 190g with display≈270g |
resolution | Analog output 0.01%FS, digital output 0.05%FS |
Output power | |
Output signal | 4~20mA,RS485,0~10VDC,0~5VDC,1~5VDC,0.5~2.5VDC |
Power supply range | 9~28VDC,15~28VDC,3~5VDC,15~24VDC |
Accuracy class | |
Measuring range≥ 100kPa | 0.25% |
10kPa≤ range < 100kPa | 0.5%FS |
Header accuracy | 0.5%FS digital tube (LED) display |
Frequency of response | |
RS485 output | 5Hz |
Absolute pressure and negative pressure | 30Hz |
The range ≤ 10 kPa | 30Hz |
other | 100Hz |
Power range | |
Voltage type | ≤0.02Us(W),≤0.008Us(W),≤0.001Us(W) |
Current type | ≤0.02Us(W) |
Digital | ≤0.02Us(W),≤0.015Us(W) |
Load characteristics | |
Voltage type | ≥10kΩ |
Current type | No display load ≤{(Us-7.5)÷0.02}Ω With display load ≤{(Us-12)÷0.02}Ω (Us=supply voltage) |
Environmental conditions | |
Ambient temperature | -40~85℃ |
Ambient humidity | 0%~95%RH (no condensation, no condensation) |
Overload capacity | |
Overload pressure | 300%FS,200%FS,12kPa,50kPa,300kPa,480kPa,750kPa,800kPa,1.2MPa,2MPa |
Burst pressure | 600%FS,500%FS,400%FS,20kPa,200kPa,600kPa,900kPa,1.25MPa,2MPa,3MPa,5MPa,2MPa,3MPa,5MPa |
Overall material | |
diaphragm | 316L stainless steel (in contact with the medium to be measured) |
Process connections | 316 stainless steel (in contact with the medium to be measured) |
enclosure | 304 stainless steel |
O-rings | Nitrile rubber (contact with the medium to be measured) |
Displays the shell | ABS Engineering Plastics (LED Display) |
Hersmann connectors | ABS engineering plastics |
Mechanical stability | |
Vibration resistance | 10g(20… 2000Hz) in accordance with the IEC60068-2-6 standard |
Impact Resistance: | 500g/ms meets IEC60068-2-27 standard |
Electrical protection | |
Short-circuit protection | perpetual |
Reverse polarity protection | No damage, but no work |
Insulation resistance | ≥100MΩ 500VDC |
Dielectric Strength: | 500VAC |
Output limits | |
The output is minimal | 4mA,0,0.001VDC,0.05VDC |
The output is maximum | 20mA,2000,10VDC,5VDC |