Add to Cart
CYYZ73CY Single Flange Type Pressure Transmitter Range -100kPa~0~4MPa Accuracy 0.5%FS Exhaust Gas Chemical Oil And Gas
The CYYZ73CY single flange pressure transmitter is designed for corrosive, viscous media. The diaphragm adopts flush membrane process (diaphragm material is 316L, tantalum, Harbin C optional). And there are a variety of explosion-proof function options, intrinsically safe type, dust intrinsically safe type, flameproof type, flameproof dust type, and can also choose HART protocol communication, cost-effective.
Base parameters | |
Measuring medium | Liquid or gas (compatible with contact material) |
Pressure range | -100kPa~0~4MPa (see range selection table for details) |
Pressure mode | Gauge pressure, absolute pressure, negative pressure |
Media temperature | -40~130℃ |
On-time | 20ms |
Accuracy class | ±0.5%FS Meter accuracy 0.5%FS (LCD with backlight) |
Temperature compensation | -10~70℃ |
Stable performance | ±0.2% FS/year |
Temperature drift | ±0.02%FS/℃ |
Ex type | Flameproof Ex db II.C T6 Gb Flameproof Dust Type Ex tb IIIC T80°C Db Intrinsically Safe Ex ia II.C T6 Ga (4~20mA/4~20mA HART output only) Dust Intrinsically Safe Ex iaD 20 T80°C (4~20mA/4~20mA HART output only). NOTE: Intrinsically safe must be powered by a safety barrier or intrinsically safe power supply |
Degree of protection | IP66 Note: The above protection level refers to the electrical connection achieved after the electrical connection is complete |
Durable performance | 10X10⁶ times (lower range to upper range cycles) |
Response frequency | Analog signal output≤ 30Hz digital signal output≤ 5Hz HART communication ≤10Hz |
Overall weight | No display≈ 1.25kg with display ≈1.4kg |
Resolution | Analog output 0.01%FS, digital output 0.05%FS |
Output power | |
output | 4~20mA,RS485,0~10VDC,0~5VDC,1~5VDC,4~20mA HART |
Power supply | 9~32VDC,13~32VDC,15~32VDC,15~24VDC |
Maximum power | |
Output signal | 4~20mA,RS485,0~10VDC,0~5VDC,1~5VDC,4~20mA HART |
power | ≤0.02Us(W),≤0.015Us(W),≤0.008Us(W), |
Load characteristics | |
Voltage type | ≥10kΩ |
Current type | No display load≤{(US-7.5)÷0.02}Ω with display load≤{(US-12)÷0.02}Ω (US=supply voltage) |
HART current type | Load ≤ {(Us-12)÷0.02}Ω(Us=Supply voltage) |
Environmental conditions | |
Ambient temperature | -40~85℃ |
Ambient humidity | 0%~95%RH(no condensation, no condensation) |
Overall material | |
diaphragm | 316L stainless steel/Ha C/tantalum (contact with the medium to be tested) |
flange | 304 stainless steel |
enclosure | Die-cast aluminum |
Display window | ≈ 6mm explosion-proof glass |
Mechanical stability | |
Seismic performance | 10g(20… 2000Hz) in accordance with IEC60068-2-6 standard |
Impact resistance: | 500g/ms conforms to IEC60068-2-27 standard |
Electrical protection | |
Short-circuit protection | perpetual |
Anti-polarity protection | No damage, but not working |
Insulation resistance | ≥100MΩ500VDC |
Dielectric strength: | 500VAC |
Output limits | |
The output is minimal | 4mA,0,0.001VDC,3.8mA |
Output maximum | 20mA,2000,10VDC,5VDC,22mA |