CYYZ11AY Universal Pressure Transmitter General Industry Use Range -100kPa~0~100MPa Accuracy 0.1%FS 0.25%FS 0.5%FS
The CYYZ11AY pressure transmitter is well designed, not only compact, but also of excellent quality, which is very suitable for general industry and cost-effective. It also has diversified advantages such as output signal, range range, pressure interface, electrical connection, etc., which is convenient to match different working conditions.
Base parameters | |
Measuring medium | Liquid or gas (compatible with contact material) |
Measuring range | -100kPa~0~100MPa (see range selection table for details) |
Type of pressure | Gauge pressure, absolute pressure, negative pressure |
Media temperature | -40~85℃ |
Temperature compensation | -10~70℃ |
Accuracy class | 0.1%FS,0.25%FS,0.5%FS |
Response frequency | 5Hz,30Hz,100Hz |
Stable performance | ± 0.1% FS/year |
Temperature drift | ±0.01%FS/°C (temperature compensation range) ±0.05%FS/°C (outside temperature compensation range) |
Overall weight | No display≈ 190g has a display ≈ 270g |
resolution | Analog output 0.01%FS, digital output 0.05%FS |
Degree of protection | IP65 (no display) IP54 (with display) Note: The above protection level refers to the electrical connection is achieved after the electrical connection is complete |
Output power | |
Output signal | 4~20mA,RS485,0~10VDC,0~5VDC,1~5VDC,0.5~2.5VDC |
Power supply range | 9~36VDC,15~36VDC,3~5VDC |
Power range | |
Current type | ≤0.02Us(W) |
Digital | ≤0.015Us(W),≤0.02Us(W) |
Voltage type | ≤0.008Us(W),≤0.001Us(W),≤0.02Us(W) |
Load characteristics | |
Voltage type | ≥10kΩ |
Current type | No display load ≤{(Us-7.5)÷0.02}Ω (US=supply voltage) |
Current type | Load ≤ shown {(Us-12)÷0.02}Ω (US=Supply Voltage) |
Environmental conditions | |
Media temperature | -40~85℃ |
Ambient temperature | -40~85℃ |
Ambient humidity | 0%~95%RH(no condensation, no condensation) |
Overload capacity | |
Overload pressure | 300%FS,200%FS,150%FS,12kPa,50kPa,300kPa,480kPa,750kPa,800kPa,1.2MPa,2MPa,3MPa,5MPa |
Burst pressure | 600%FS,500%FS,400%FS,300%FS,20kPa,200kPa,600kPa,900kPa,1.25MPa,2MPa,3MPa,5MPa,9MPa,12.5MPa |
Overall material | |
diaphragm | 316L stainless steel (contact) |
Process connection | 304 stainless steel (contact) |
enclosure | 304 stainless steel (contact) |
Seals | Nitrile rubber (contact) fluoroelastomer (seen pressure and blasting chart (contact with the medium to be measured) |
Hirschmann joints | ABS engineering plastics, |
Mechanical stability | |
Seismic performance | 10g(20… 2000Hz) |
Impact resistance: | 500g/ms |
Electrical protection | |
Short-circuit protection | perpetual |
Anti-polarity protection | No damage, but not working |
Insulation resistance | ≥100MΩ500VDC |
Dielectric strength: | 500VAC |
Output limits | |
The output is minimal | 4mA,0,0.001VDC,0.05VDC |
Output maximum | 20mA,2000,10VDC,5VDC |